Quantitative CO Analysis for Complex Gas Mixtures

Designed to complement Hiden HPR-20 and QGA 2.0 Gas Analysis systems, the CO Analyser delivers accurate quantitative analysis of carbon monoxide within complex gas matrices. It resolves overlapping background signals from nitrogen, carbon dioxide, and methane in syngas, biogas, and catalysis applications.

 

Overview

The next-generation CO Analyser is an advanced gas sensing module designed to seamlessly integrate with our Mass Spectrometry (MS) systems. Engineered to overcome the classic analytical challenge of resolving carbon monoxide in overlapping background matrices, it provides high-speed, high-precision quantitative analysis for demanding research and industrial applications.

  • Mass Spectrometer Integration: Fully synchronised with mass spectrometer hardware and software for unified gas analysis and streamlined data acquisition.
  • Overcomes Complex Matrix Interference: Optimised for catalysis, syngas, and biogas studies—delivering reliable CO quantification in multi-component mixtures (e.g. N2, CO2, CH4).
  • Heated & Pressure-Compensated Housing: Designed with an integrated heated enclosure and automatic pressure compensation, featuring 1/8″ Swagelok® gas connections for leak-tight sampling.
  • Rapid Response Time: Delivers real-time continuous monitoring with an ultra-low response time of just 1.6 seconds.
  • Versatile Range Selection: Available in a wide variety of customisable measurement ranges to suit diverse process requirements.

Standalone CO Analysers with measurement ranges: 0.04 – 1,000 ppm and 0.04 – 10,000 ppm are also available, with data acquisition integrated to the Hiden mass spectrometers.

Features

  • Dimensions: 90 x 59 x 180 mm (H x D x L)
  • Measurement ranges available from 0-2000 ppm to 0-100%
  • Response time (t90): 1.6 s at 700 ml/min non-condensing
  • Detection limit: between 10 ppm and 500 ppm, depending on the range selected
  • Repeatability: between ±0.4% and ±1% of the full scale, depending on the range selected
  • Linearity error: ≤ ± 1% of the full scale
  • Long term stability (calibration): between 1% and 15% of the full scale, depending on the range selected
  • Gas connection: 1/8″ Swagelok

Further Reading

The system is supplied with MASsoft Professional Edition software.

This Windows 10 and Windows 11 compatible software allows control of the instrument via USB 2.0, RS232 or Ethernet. Provides comprehensive I/O for data output and for reading data from external devices for integration and display with mass spectrometer data.